Diesel engine warm-keeping electrical installation for generator sets
IEMC Generator Group
Presentation
The installation is designed to ensure that the liquid in the cooling circuit of Diesel engines, existing on drilling units or generator sets, is kept warm.
It is made in one or two power stages, the second stage being connected automatically depending on the temperature of the coolant. Having a double casing, the installation can be used in unprotected spaces or in bad weather environments.
Product Code IEMC 15P IEMC 21.1P Supply voltage 3x400V/220V 3x400V/220V Frequency 50Hz 50Hz Installation power 15 kW 21.1 kW return 0,98 0,98 Working temperature 45-50˚C 45-50˚C Protection temperature 90˚C 90˚C Recirculated flow 3m³/h 3m³/h Aspiration 1´´ 1´´ repression 1´´ 1´´ Installation weight 45kg 45kg Overall dimensions (mm) 555x380x750 555x380x750 Machine type
on which it is mountedGenerator set Generator set Upon request, it can be made at any power, depending on the beneficiary's needs.